top of page

POST

Issue in Phasor panel popup menu commands

Updated: Jan 2, 2024

We had discovered that two popup menu commands in the phasor panel: "Print text result to TTY window" and "Copy text result to windows clipboard" could produce inaccurate results when the phasor panel angle reference is set to something other than System.


This error had been fixed in OneLiner version 14.6 with build number 50128 and higher (Program version and build number are displayed in OneLiner Help | About dialog box).


Users should contact ASPEN support to request program update with the bug fix.

Recent Posts

See All
OneLiner iterative solution

We discovered a software bug in the simulation results reporting logic in OneLiner V15.7 and earlier. When the iterative solution of some...

 
 
 