OneLiner V15.5 fault current calculation in networks with Converter Interfaced Resources

We had discovered that copies of the OneLiner V15.5 that users downloaded from ASPEN between January 13 and February 25, 2022, contained a software bug that caused incorrect fault calculation results in some networks with Converter Interfaced Resources. This software bug had been fixed in OneLiner V15.5 Build 19846 or higher (The program build number is displayed in the OneLiner Help | About dialog box). Users should contact ASPEN support <support@aspeninc.com> to request a software update with the latest bug fixes.

Recent Posts

See All
OneLiner iterative solution

We discovered a software bug in the simulation results reporting logic in OneLiner V15.7 and earlier. When the iterative solution of some...

 
 
 